I HAVE A PACKED DECIMAL FIELD WHICH IS REDEFINED TO A NUMERIC FIELD TO ADD "1" TO ITS TENTH DIGIT. For more information about the Hex-Dump format refer to the Hexadecimal Dump Format section of this document. 02 IMPME-OUT PIC S9(13)V9(2) COMP-3. COBOL Comp-3 (Computational-3) Packed Fields: What they are. - A Disc Example: Data: begin of itab occurs 0, ebeln like ekko-ebeln, ebelp like ekpo-ebelp, menge (15) type p decimals 2, netpr (15) type p decimals 2, end of itab. When a text file contains packed numbers or any other kind of binary REFFILE. The OUTPUT will contain the numeric data: BROWSE your.CONVERT.OUTPUT Line 0000000000 Col 001 080. a mainframe environment to SQL Server. Styling contours by colour and by line thickness in QGIS, Equation alignment in aligned environment not working properly, Implement Seek on /dev/stdin file descriptor in Rust. Move X (05) to packed field S9 (10) COMP-3. 01 DATAREC1NEW. The fewer decimal positions of the result field will be rounded because of the ROUNDED keyword on the ADD statement. This program (NBRCVTC1.cbl) was written to show various techniques for converting between various Packed numeric field formats used on the mainframe and/or with the COBOL programming language. The following is a flowchart of the job for executing the programs that show the conversion between the various numeric field types. . what is happeing here is that the packed decimal is chopped in bytes and passed as an array. The naming of a job script is determined by the Operating System. Thanks everyone for the replies..now i know more than one method that wud work. byte [] pd = args [0] .getBytes () will build a byte array = {0x11, 0x23, 0x4D} this will result in -11234. Lemme know what do you think. Why do many companies reject expired SSL certificates as bugs in bug bounties? I have a amount field in my Input file containing Comp-3 value and I want it to convert into comp-2 value . I need to convert 10-15 different files in the differernt JCL, So I want . The possible translated, displayable ASCII characters are (highlighted in red). The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies. Dictionary debit type category debit value debit, to debit, to debit-side settlement debit/credit amount debited interest debiting and crediting an account debits debits and credits debits/credits indicator debt discount debt instrument debt instrument debt register debt to total capital debt-equity ratio debtor debug debugging debugging . First we are going to create a sample database. Dick: you can redefine a packed decimal value to floating point by completely and totally changing the value, making it pretty much unrelated to the original value? :http://www.microsoft.com/en-us/download/details.aspx?id=20397. Packed-decimal (Comp-3) is there any way to fix this issue without making use of another variables (e.g. for more information about products (including Micro Focus COBOL) and services available from Micro Focus. Also Explore The Edited for Display format for numeric data strings. It's simply. Help? It consists of the word PIC or PICTURE followed by the actual picture clause, where the type and size are specified. The problem with moving it to a numeric field is that ABCDEF are actually valid zoned-decimal digits. Difference between "select-editor" and "update-alternatives --config editor". which is a slight modification to my previously posted code, has been tested and correctly adds 1 to the 10th digit -- same output as previously posted. Converting numbers. previous tip, SSIS offers us the possibility to extend its functionality by AFTER THIS IT NEED BE AGAIN CONVERTED BACK INTO PACKED DECIMAL INORDER TO INSERT THIS FIELD INTO A TABLE. This program (NBRCVTC2.cbl) was written to show various techniques for converting between various Binary numeric field formats used on the mainframe and/or with the COBOL programming language. The Picture clause is used to specify the type and size of an elementary data item. how to convert decimal to Packed decimal/COMP-3, Having trouble unpacking Comp-3 in .Net. The only difference is that my mainframe file has one packed field that looks like:1469, 300CI have the File connection manager set to DT_BYTES with an output column width of 4. For eg., i have alphanumeric string 'ABCDEF 0 0.450' and i need to get '0.450' as numeric decimal and do arithmetic on it. we must set the TextQualified option to False. Using V6.2 and ARCH(12), the compiler instead uses the vector packed-decimal facility, which accelerates packed and zoned decimal computation by storing intermediate results in vector registers instead . 1. T gives right-alignment, U gives left-alignment. The function delivered in this version is based upon the enhancement requests from a specific group of users. How to convert Decimal Values to Strings in COBOL Connect and share knowledge within a single location that is structured and easy to search. I have to convert it. One copybook for the source data structure and one for the new data structure. Refer to the Downloads and Links to Similar Pages section of this document for links that provide additional detail about numeric formats. To convert that field in Easytrieve Plus, you'd need to write some code, a loop starting at the right, ignoring blanks. This test case will show the process for converting a zoned-decimal-numeric format to a display (or zoned-decimal) format. Since packed decimal data you can't read in the EDIT field, you can specify a format you want for display. Instead we have to use the DT_BYTES What is the significance of the code at right of variable declaration in COBOL? If the packed decimal is 0x11234D. How to use Slater Type Orbitals as a basis functions in matrix method correctly? Studio Editor gives us a Class Template to add our code onto it. Find centralized, trusted content and collaborate around the technologies you use most. Refer to if itab-menge has a value of 2.00, i need to convert that value to ' 200'. According to the files record definition we will configure columns Name and To subscribe to this RSS feed, copy and paste this URL into your RSS reader. 9(3) is a three digit numeric, and COMP-3 is BCD encoded decimal. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP" or "USAGE IS BINARY" clause. The last digit goes in the upper nibble of the last byte. I believe, the receiving fields should be 'STRING's too. The Source Field is defined as a Binary (or COMP) field with 6 digits and 3 decimal positions. Connect and share knowledge within a single location that is structured and easy to search. For the Nozomi from Shinagawa to Osaka, say on a Saturday afternoon, would tickets/seats typically be available - or would you need to book? asking us how we want to use this Script Component. 02 TETI-OUT PIC X(4). How to convert Python variables into equivalent cobol group variables? Cron <gccadmin@sourceware> sh /home/gccadmin/scripts/update_web_docs_svn We are going to instruct the SSIS pipeline Note that the IF test is critical since the original problem staement indicated that there's a very good chance the AMOUNT field is not numeric to start with. Did this satellite streak past the Hubble Space Telescope so close that it was out of focus? 02 FIELD1-PCK PIC 9(08)V99 COMP-3. Redefine the 2-byte alphanumeric variable as PIC S9 (04) COMP. This test case will show the process for converting a binary numeric format to an edited numeric format. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration. Here is a little different attempt at answering your questions. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document. The Result field is also defined with a SIGN TRAILING SEPARATE that creates an additional byte to the field for the sign. If the definition size matches there shouldn't be any truncation. if itab-menge has a value of 2.00, i need to convert that value to ' 200'. The session will describe three of the popular numeric formats used with COBOL and IBM Mainframe systems. Re: EZT - Data conversion from Alphanumeric to Packed decima. Therefore, when the field is used in the calculation specifications, the result field must be nine positions long. we need to select DT_BYTES as the Data Type; and 1 and 6 for its lengths and view the COBOL source code for this numeric field conversion example. Did any DOS compatibility layers exist for any UNIX-like systems before DOS started to become outmoded? In the world of programming there are many ways to solve a problem. Else please lemme know if that was not you were looking at. Use the language as it was intended to be used. Considering that back in a day the cost for storage and memory was COMP-3 occupies INT(N+1/2) by. 02 CAUSAL-OUT PIC X(3). To learn more, see our tips on writing great answers. The following (NBRCVTE2.cmd) is a sample of the Windows CMD needed to run this job in a non-Mainframe environment. and view the COBOL source code for this numeric field conversion example. EZT - Data conversion from Alphanumeric to Packed decimal - CA-Easytrieve Define a 2-byte alphanumeric variable (group or elementary). The following (nbrcvts3.sh) is the Bash Shell Script needed to run this job on a Linux or UNIX System using GnuCOBOL. Is it possible to create a concave light? Little Endian - within a sixteen or thirty-two bit word the bytes at lower addresses have lower significance. Another instance of Visual can be converted to numeric values via File Master using COBOL copybooks. The decimal point is implied. Decimal value turns into 00 when displayed in cobol, convert alphanumeric PIC X(02) to hex value 9(01) COMP-3 in cobol. Staging Ground Beta 1 Recap, and Reviewers needed for Beta 2, How do I convert an integer value to decimal value in COBOL. The next step is to create a SSIS project and add a Data Flow task, a Flat File For detailed information on DFSORT's numeric conversion parameters, see z/OS DFSORT Application Programming Guide. JCL- Sort 'PD' to 'ZD' with Length Calculation - Srinimf Explore The File Status Return Codes to interpret the results of accessing VSAM data sets and/or QSAM files. This document describes how packed decimal values (Computational-3) can be converted to numeric values via File Master using COBOL copybooks. Difference between "select-editor" and "update-alternatives --config editor". Your email address will not be published. The sign indication is dependent on your operating environment. You are right, the issue is in that definition. It is implemented as "comp-3". This assumes the string value is made up of 3 parts separated by spaces. database using The following is the WORKING-STORAGE definition for the source field. Thanks for contributing an answer to Stack Overflow! i have a question on data type conversion. My code is GPL licensed, can I issue a license to have my code be distributed in a specific MIT licensed project? To learn more, see our tips on writing great answers. The next image may be used as a guide. 02 FILLER PIC X(72). Connect and share knowledge within a single location that is structured and easy to search. Such a REFFILE will be created via File Master ISPF 3.11 menu ("11 REFORMAT Convert file from one record layout to another").You need two COBOL data structures, aka. Now we are ready to execute the SSIS package and after it completes we can perform Explanation: For a comp-3 packed field specifies the number of digits after unpacking. At the end of the exercise variable Y contains something that is readable and makes sense to the normal human eye. Refer to able to handle this field as a string. Thanks for contributing an answer to Stack Overflow! This section provides various test cases for converting different types of numeric fields. I included two functions to handle data conversion: Translate and This represents a number +6150000 with picture clause of S9(7) COMP-3. The next step is to set up the Inputs and Outputs tab. at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.HandleUserException(Exception e) at Microsoft.SqlServer.Dts.Pipeline.ScriptComponentHost.ProcessInput(Int32 inputID, PipelineBuffer. It is so important that Move the 1-byte to the second byte of the 2-byte variable (directly if the 2-byte variable is a group of 2 1-byte . CCURE 9000 AC9001 Installer/Maintainer Student Guide Appendix A 106. fPerformance Exam 1 (PE1) The scoring for Performance Exam 1 (PE1) is based on a three-part score. Next is a table that reviews the functions and procedures used in this tip. How do you convert packed decimal to numeric in COBOL? Asking for help, clarification, or responding to other answers. The nature of simulating nature: A Q&A with IBM Quantum researcher Dr. Jamie We've added a "Necessary cookies only" option to the cookie consent popup. JCL Procedure: Instream, Catalogue, Nested. How to convert packed decimal values to numeric values via File Master using COBOL copybooks This document describes how packed decimal values (Computational-3) can be converted to numeric values via File Master using COBOL copybooks.The only method to get this done is to use a File Master Reformat data set, aka. WRITE WORK does not allow format specifications nor edit masks. Here I used SORT FIELDS=COPY is equal to OPTION COPY. And Please suggest any other way to achieve the same! A suitable definition for a table to load this file is next. Moving packed-decimal (PIC S9(11)V99 COMP-3) to zoned-decimal (PIC S9(11)V99) is completely valid - providing the comp-3 data is properly signed numeric. Copyright 1987-2023SimoTime Technologies and ServicesAll Rights Reserved. But as I told you in my It is comp of some kind. To The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources. COBOL Computational Fields: comp, comp-3, packed decimal, binary - A COBOL Comp-3 is a binary field type that puts ("packs") two digits into each byte, using a notation called Binary Coded Decimal, or BCD. Where developers & technologists share private knowledge with coworkers, Reach developers & technologists worldwide, Interpreting COMP-3 Packed Decimal Fields into numeric values, http://jrecord.cvs.sourceforge.net/viewvc/jrecord/jrecord/src/net/sf/JRecord/Common/Conversion.java?revision=1.2&view=markup, How Intuit democratizes AI development across teams through reusability. I assume the format is not fixed, since then you could just pick that part of the string and move it to a field defined with pic 9.999 and use it from there. Enter 2 and 3 in the TO section of the panel, for example: CA File Master Plus -- Reformat your.CONVERT.LIB(REFORMAT), ------------------------------------------------------------------------------. Making statements based on opinion; back them up with references or personal experience. For more information about conversion between data types check out this Do we have a way? Negative zero behaves the same as positive zero computationally. Depending on what you want Y to contain, no. on the properties frame set to true the UseBinaryFormat property. WikiZero zgr Ansiklopedi - Wikipedia Okumann En Kolay Yolu For most numeric processes, RPG implicitly converts numeric values to packed decimal format before processing them.